TEL: Facebook/wechat/WhatsApp:+8619936624847 LINE:daqiot

RS485 Split Core Current Sensor

RS485 Split Core Current Sensor

DAQ-GP-CT485


1. Easy Installation – Split Core Design

2. Industrial IoT Ready (RS485 Modbus Output)

3. High Accuracy Current Measurement

4. Real-Time Remote Monitoring

5. Industrial-Grade Reliability

6. Easy System Integration

7. Cost-Effective Smart Monitoring Solution

8. Free Remote Technic Support


Product Details


 1. Product Overview

6df73a274a44dd0cb97f2f13858d16bc.png

 

DAQ-GP-CT485 split core current transformer is a kind of current sensor (transformer) which can convert AC analog signal into RS485 digital signal launched by Shanghai Data Acquisition IOT Technology Co., LTD. The product has built-in 32-bit ARM series MCU and high-precision metering chip, and is a multi-point calibrated current conversion module. It has the characteristics of high precision and fast response. DAQ-GP-CT485 can directly interact with common data acquisition gateways, DTU, programmable controller PLC, and host computer.

This product is widely used in AC motor, lighting equipment, air compressor, heating ventilation and air conditioning equipment, building self-control system, equipment OEE open rate, industrial Internet, rural power transformation projects and other scenarios of current monitoring and acquisition scenarios.

2 Service Concept

Our company solemnly promise you:

You buy more than just products, but also meticulous and thoughtful technical support. 

We provide free remote guidance, remote configuration and commissioning services, and send data to the server specified by the customer.

Free IOT solution consulting services!

3 Product Characteristic Parameters

Line Sequence Definition

Red:+12V   Black:GND  Yellow:485A  White:485B

Length of Line:Default 1 meter

Acquisition Characteristic

l Current detection range:  AC 0.2A-100A,Other large range transformers can be customized

Electrical Characteristic

l Power supply mode:5~24V DC

l Operating power consumption:0.5W

l Operating frequency:50-60Hz

Communication Characteristic

l Transmission mode:RS485 

l Communication protocol:  Modbus RTU

Structural Characteristic

l Material:ABS plastic (enclosure)

l Installation method:Buckle mounting

Working Environment

l Temperature: -20°C~70°C

Storage Environment

l Temperature: -20°C~80°C

4 The Core Advantages of the Product

Ø High precision measuring chip, high measurement accuracy

Ø Open type design, easy to install

Ø Easy installation and fast deployment, helping IOT projects land quickly

5 Description of the Modbus Communication Protocol

 

5.1 Serial Port Communication Parameters

Baud rate:9600      Data bit:8      Verify:NONE      Stop bit:1

5.2 Function Code Definition

The upper computer uses 03 function code to read data or receive alarm data.

The host computer controls the lower machine equipment (transformer) using 06 function code.

5.3 Register Point Table Definition

Register table:

Serial number

Register address

Instructions

Read/Write

Data type

1

0x01

Device address (default 1)

Read/Write

16-bit

2

0x02

Sensor data is 16 bits higher

Read

16-bit

3

0x03

Sensor data is 16 bits lower

Read

16-bit

4

0x04

Baud rate

Read/Write

16-bit

5

0x05

Reserve


16-bit

6

0x06

Reserve


16-bit

7

0x07

Reserve


16-bit

 

5.4 Communication Packet Examples

Give an example:

Host reads the sensor value:

1

2

3

4

5

6

7

8

Device address

Function code

The register address is 8 bits higher

The register address is 8 bits lower

The number of read registers is 8 bits higher

The number of read registers is 8 bits lower

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x03

0x00

0x01

0x00

0x02

0x95

0xCB









Return data from slave:

1

2

3

4

5

6

7

8

9

Device address

Function code

Number of bytes

Register value [31:24]

Register value [23:16]

Register value [15:8]

Register value [7:0]

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x03

0x04

0x00

0x00

0x27

0x10

0xE0

0x0F

The register value is 0x00002710, and the decimal notation is 10000. Assuming that the AC transformer ranges from 0 to 100A, the current is 100A.

Changing a device address:(0x01 is changed to 0x02)

Host sending:

1

2

3

4

5

6

7

8

Device address

Function code

The register address is 8 bits higher

The register address is 8 bits lower

The register value is 8 bits higher

The register value is 8 bits higher

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x06

0x00

0x00

0x00

0x02

0x08

0x0B

Return data from slave:

The new address takes effect only after the current device address is returned from the slave.

1

2

3

4

5

6

7

8

Device address

Function code

The register address is 8 bits higher

The register address is 8 bits lower

The register value is 8 bits higher

The register value is 8 bits higher

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x06

0x00

0x00

0x00

0x01

0x48

0x0A

 

Modified baud rate:(9600 is changed to 1200)

Host sending:

1

2

3

4

5

6

7

8

Device address

Function code

The register address is 8 bits higher

The register address is 8 bits lower

The register value is 8 bits higher

The register value is 8 bits higher

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x06

0x00

0x04

0x00

0x02

0x49

0xCA

Return data from slave:

1

2

3

4

5

6

7

8

Device address

Function code

The register address is 8 bits higher

The register address is 8 bits lower

The register value is 8 bits higher

The register value is 8 bits higher

The CRC is 8 bits higher

The CRC is 8 bits lower

0x01

0x06

0x00

0x04

0x00

0x02

0x49

0xCA

(Note: The baud rate takes effect only after the device is powered on again. Change back to 9600 host and send 01 06 00 04 00 05 08 08)

Baud rate register (0x04) Value description:

Register address

Register value

Attributes (Baud rate)

0x04

0x00

300

0x01

600

0x02

1200

0x03

2400

0x04

4800

0x05(Factory default)

9600

0x06

19200

0x07

38400

0x08

43000

0x09

56000

0x0a

57600

0x0b

115200

If the baud rate is set outside the range, the slave will return the current register value without changing the baud rate.

6 Application Cases

78316dacdc155c54f62110d3b7da4cc4.png

d48cb68c3ba5e5470423bafbb1325833.png 

Collection of current data of production equipment in textile factory

In this case, 4G wireless open-type AC sensor is used to collect current data, and the data is displayed on the cloud platform. The data can be accessed and viewed through websites, apps, WeChat mini programs, etc.


❓ RS485 Split Core Current Sensor – FAQ

1. What is an RS485 Split Core Current Sensor used for?

It is used for real-time current measurement in industrial IoT systems, energy monitoring, and power distribution management without interrupting the power line.

2. What is the advantage of a split core design?

The split core design allows installation without disconnecting cables or shutting down equipment, making it ideal for retrofit and live electrical systems.

3. What communication protocol does it support?

It supports RS485 Modbus RTU protocol, enabling easy integration with PLC, SCADA, and IoT energy monitoring platforms.

4. Can it be used for remote monitoring?

Yes, it can transmit real-time current data to IoT gateways or cloud platforms for remote monitoring and energy management.

5. How accurate is the current measurement?

The sensor provides high-precision and stable current measurement with strong anti-interference capability suitable for industrial environments.

6. What systems can it integrate with?

It can be integrated with PLC systems, SCADA systems, energy management systems (EMS), and industrial IoT platforms.

7. Where is this current sensor commonly used?

It is widely used in smart factories, industrial automation, power distribution systems, solar PV systems, and wind energy monitoring.

8. Does it require power interruption during installation?

No. The split core design allows installation without interrupting power, ensuring safe and fast deployment.