TEL: Facebook/wechat/WhatsApp:+8619936624847 LINE:daqiot

Landis+Gyr E650 Electricity Meters

Landis+Gyr E650 Electricity Meters

AMI Smart Metering System Solution for Utilities & Smart Grid | Remote Energy Data Acquisition & Monitoring Platform

📌 Solution Overview

The AMI (Advanced Metering Infrastructure) Smart Metering System is an integrated energy data acquisition and management solution designed for utilities, power distribution companies, and large-scale industrial energy users.

It enables real-time, two-way communication between smart electricity meters (such as Landis+Gyr E650 and similar devices), data concentrators, and central management platforms.

This system helps utilities achieve accurate billing, remote meter reading, load analysis, and smart grid optimization, significantly reducing manual labor costs while improving grid efficiency and transparency.

⚙️ System Architecture

The AMI smart metering system typically consists of:

1. Smart Electricity Meters

Three-phase / single-phase smart meters

Support DLMS/COSEM communication protocol

High accuracy energy measurement (Class 0.2S / 0.5S)

Tamper detection and event logging

2. Communication Network

RF / PLC (Power Line Communication) / GSM / 4G / NB-IoT

Secure two-way data transmission

Supports hybrid communication architecture for large deployments

3. Data Concentrator Unit (DCU)

Aggregates meter data from multiple endpoints

Edge computing and local data storage

Protocol conversion (DLMS, Modbus, TCP/IP, etc.)

4. Head-End System (HES) / Cloud Platform

Centralized data management platform

Real-time monitoring dashboard

Billing and energy analytics system

Alarm management and reporting tools

🌍 Key Functions & Features

Real-time remote meter reading (AMR/AMI)

Automated billing and energy consumption tracking

Load profiling and demand analysis

Power quality monitoring

Tamper and fraud detection

Outage and fault detection

Multi-site centralized energy management

Historical data storage and reporting

🏭 Typical Applications

Power utility companies

Smart grid infrastructure projects

Industrial parks and factories

Commercial buildings and real estate

Renewable energy systems (solar/wind farms)

Smart city energy management

📊 Supported Communication Technologies

DLMS/COSEM protocol

RS485 / Optical port

PLC (Power Line Communication)

GSM / GPRS / 4G LTE / NB-IoT

MQTT / TCP/IP / API integration

🔐 System Advantages

Reduces manual meter reading cost

Improves billing accuracy and transparency

Enables real-time grid monitoring

Supports predictive energy management

Scalable for millions of endpoints

Easy integration with existing utility systems


Product Details


图片1.png

The Landis E850 series of high-end gateway settlement watt-hour meters are specially used for gateway settlement of regional power grids and power plants with high voltage levels, as well as large industrial and commercial users such as electrified railways with frequent load changes. With excellent measurement accuracy, significantly high refresh rate, and long-term stable and reliable operation, they have successfully won the unanimous praise and trust of users around the world.

Widely used in:

Gateway power grids and substations in provinces across the country.

● State Grid UHV and China Southern Grid EHV.

● Guangdong-Hong Kong cross-border power grid, Zhuhai-Macao cross-border power grid, Guangdong-Hainan cross-sea power grid.

● Nuclear power, thermal power, wind power, hydropower, photovoltaic and other power plants, the Three Gorges Hydropower Station on the Yangtze River, pumped storage and other projects.

● Traction station projects on numerous high-speed rail lines.

Basic Functions

● Accuracy 0.2S level

● Application CT/PT connection

● Massive data records

42 test data

42 test data

40 frozen power curves

Power Factor Register

Flow direction register

Power loss

41 diagnostic data

U, l, F, harmonic voltage, current

24 rate registers

4 demand registers P, Q or S

Maximum demand register

64-register power quality voltage sag meter

Can record 256 events and alarms of 128 different types

● Standard features

Three-phase PT circuit and auxiliary power supply are powered in parallel to achieve uninterrupted switching (optional auxiliary power supply is independent)

Internal real-time clock with power backup

Installation support display

One meter with multiple ranges (configurable)

Two sets of load curves (different integration periods)

Contactless meter reading

Supercapacitor can support internal clock operation for more than 20 days

Programmable main pulse output terminal

LCD display with backlight

● Advanced features

Instantaneous value measurements, including voltage, current, phase angle, power factor and grid frequency

Harmonic measurement, including 30th harmonic voltage, current and active energy

Loss measurement

Monitor alarm light indication, can also be set as relay output node

Phase loss and phase sequence error warning

Each phase pressure loss monitoring alarm, etc.

● Configurable communication unit CU

model

Interface Type

Regulations

Z6

RS485, RS485

DL/T645(97/07), DLMS, IEC1107

Z8

RS485, RS485, RS485

DL/T645(97/07), DL/T698.45, DLMS, IEC1107

XE

10/100BASE-TX, RS485/RS422, RS232

DLMS, Modbus, IEC608 70-5-104, DLT860 (61850)

● Typical technical data

Measurement accuracy: active 0.2S level, reactive 0.5/1.0 level

Reference voltage

Un 3 x 100V, 3 x 110V, 3 x 115V, 3 x 220V, 3 x190V~3 x 230V (user-defined)

Measuring voltage range

70%-115%Un

Nominal current

0.31.2)A, 0.3(6)A, 1(2)A, 1.5(6)A, 5(6)A

Starting current

0.05%In (standard value)

Typical power consumption

Current loop 1A: 0.004VA: 5A: 0.09VA; Voltage loop 0.9VA (0.5W) (standard auxiliary power mode) 1.4VA (0.8W) (auxiliary power supply + output contact + communication module)

Nominal frequency

fin 50/60Hz, working range 90%~110%

Auxiliary power supply

110-220V AC/DC, 24-125V AC/DC (optional) Maximum power consumption 6VA

Calendar clock

Accuracy [5ppm (25°C): Battery powered operation time 10 years: Supercapacitor (no battery) operation] 20 days

interface

Support 3 independent RS485 interfaces

Protection level

IP51

Installation Dimensions

173mm(W) x 281.6mm(H) x 75mm(D)

 

❓ Frequently Asked Questions (FAQ)

1. What is an AMI smart metering system?

AMI is an advanced system that enables two-way communication between smart electricity meters and utility management platforms for real-time data collection and remote control.

2. What is the difference between AMR and AMI?

AMR (Automatic Meter Reading) only collects data one-way, while AMI allows two-way communication, enabling remote configuration, diagnostics, and real-time monitoring.

3. Can Landis+Gyr E650 be used in AMI systems?

Yes. The E650 smart meter is fully compatible with AMI infrastructure and supports DLMS/COSEM and multiple communication modules for integration.

4. How is data transmitted in the AMI system?

Data is transmitted through RF, PLC, cellular networks (4G/NB-IoT), or hybrid communication systems depending on project requirements.

5. Is the system suitable for large-scale utility deployment?

Yes. AMI systems are designed for mass deployment, supporting thousands to millions of smart meters in a centralized platform.

6. Can the system detect energy theft or tampering?

Yes. The system includes anti-tamper detection features such as magnetic interference, reverse energy flow, and meter cover opening alarms.

7. Can the platform integrate with existing utility software?

Yes. The system supports API, MQTT, and standard communication protocols for integration with SCADA, ERP, and utility billing systems.

8. Is remote firmware upgrade supported?

Yes. Many AMI systems support OTA (Over-the-Air) firmware upgrades, enabling remote maintenance and system optimization.

🚀 Call To Action (CTA)

Upgrade your energy management with a scalable AMI smart metering solution.

👉 Request System Architecture Diagram

👉 Get Technical Consultation

👉 OEM / Utility Project Cooperation Available

👉 Contact Us for Pilot Deployment